Only five models for all flow range, set all functions of electronic metering pumps in one. Every model use PVDF pump head.
Standard Configuration: PVDF pump head and ceramic ball valve
The diaphragm has been tested over a period of 5 years.
Pumps can steady operation in range from 100 to 240 Vac.
Include foot filter, injection valve, fixing bracket, suction tube and delivery tube.
Series
| AKS | analog | manual adjustable |
| AKL | manual adjustable, with liquid probe interfaces | |
| APG | manual adjustable proportional flow rate: external analog signals (4-20mA) or external digital signal (water meter), with liquid probe interfaces |
|
| TPG | digital | manual adjustable proportional flow rate: external analog signals (4-20mA) or external digital signal (water meter), with liquid probe interfaces |
| TPR | manual adjustable, proportional flow rate: built-in PH/ORP monitor controller |
| Model | Pressure (Bar) |
Flow Rate (L/H) |
Connections In/Out(mm) |
Max frequency (stroke/min) |
Power (Watt) |
GW (Kg) |
Packing size L*W*H(mm) |
| 500 | 20 | 0.4 | 4 / 6 inhale 4 / 7discharge |
120 | 15 | 4.1 | 298*195*250 |
| 16 | 0.8 | ||||||
| 10 | 1.2 | ||||||
| 6 | 1.5 | ||||||
| 600 | 20 | 2.5 | 4 / 6 inhale 4 / 7discharge |
120 | 20 | 4.3 | |
| 18 | 3 | ||||||
| 14 | 4.2 | ||||||
| 8 | 7 | ||||||
| 603 | 12 | 4 | 4 / 6 | 160 | 20 | 4.3 | |
| 10 | 5 | ||||||
| 8 | 6 | ||||||
| 2 | 8 | ||||||
| 800 | 16 | 7 | 4 / 6 | 300 | 40 | 4.3 | |
| 10 | 10 | ||||||
| 5 | 15 | ||||||
| 1 | 18 | ||||||
| 803 | 5 | 20 | 8 / 12 | 300 | 40 | 4.3 | |
| 4 | 25 | ||||||
| 2 | 38 | ||||||
| 0.1 | 54 |