Characteristics Cooling Efficiency System Easy to move and install at any place with a small size and attached Caster Simple, good looking,and comfortable controller for using. Use of IN, OUT Ball valve made in Italy
For Safety Built-in circuit for inversion prevention and electricity detection Protecting for Over-Curren The pressure is controlled automatically & It has function of emission Strainer Air Purge Bypass Pipe for Oil control When the pressure of Circuit route is too high, it can be used
| Model | For water | DHMW-30 | DHMW-60 | DHMW-90 | DHMW-120 | DHMW-150 |
| For oil | DHMO-30 | DHMO-60 | DHMO-90 | DHMO-120 | DHMO-150 | |
| Medium | For water | (Clean Water) | ||||
| For oil | (Thermia oil) | |||||
| Cooling method | For water | (Direct/indirect cooling method) | ||||
| For oil | (Indirect cooling method) | |||||
| Temperature regulation range | For water (℃) | Feed water temperature ~ Max. 130℃ | ||||
| For oil (℃) | 40℃ ~ Max. 150℃ | |||||
| Heater (Kw) | 4 | 6 | 9 | 12 | 15 | |
| Pump | Seal type | (Mechanical seal) | ||||
| Out put (Kw) | 0.7 | 1.2 | 1.5 | 1.5 | 2.0 | |
| Max. flow (ℓ/min) | 60 | 60 | 100 | 150 | 200 | |
| Tank capacity | For water (ℓ) | 5 | 8 | 12 | 15 | 15 |
| For oil (ℓ) | 2.5 | 5 | 5 | 5 | 5 | |
| Aux. tank | For water (ℓ) | 2.5 | 5 | 5 | 5 | 5 |
| For oil (ℓ) | 5 | 8 | 12 | 15 | 15 | |
| Cooler (A) | 15 | 20 | 25 | 25 | 25 | |
| Temperature control | PID control | |||||
| Pipes | Outlet for medium (A) | 15 | 20 | 25 | 32 | |
| Reduction in medium (A) | 15 | 20 | 25 | 32 | ||
| Inlet for coolant (A) | 10 | 15 | ||||
| Outlet for coolant (A) | 10 | 15 | ||||
| Water discharge (A) | 15 | 20 | 25 | |||
| Total Power Consumption (Kw/h) | 5 | 7.75 | 10.5 | 14 | 17 | |
| Dimension (LxWxH) | 640x280x530 | 700x340x630 | 730x340x630 | 835x340x630 | 880x470x680 | |
| Power (V) | AC 3Φ 220/380V 50/60Hz | |||||
| All the deatils can bg changed without any notice with the products developed. | ||||||